RE-2Y(St)2YSWAY-fl-PIMF

RE-2Y(St)2YSWAY-fl-PIMF

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 2MULTİ-PAİR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation: PE compound, BS 6234 Type03 Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Standard: BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BayEnergy® N2X2Y-O  0,6/1 kV  vieladrig

BayEnergy® N2X2Y-O 0,6/1 kV vieladrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy®  N2XCY  0,6/1 kV  1-2-adrig

BayEnergy® N2XCY 0,6/1 kV 1-2-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind und unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BayEnergy® N2X2Y-J  0,6/1 kV  vieladrig

BayEnergy® N2X2Y-J 0,6/1 kV vieladrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy®  NA2X2Y-J  0,6/1 kV  4-adrig

BayEnergy® NA2X2Y-J 0,6/1 kV 4-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy® N2X2Y-J  0,6/1 kV  1-adrig

BayEnergy® N2X2Y-J 0,6/1 kV 1-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy® N2X2Y-O  0,6/1 kV  1-adrig

BayEnergy® N2X2Y-O 0,6/1 kV 1-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BayEnergy® NA2X2Y-O  0,6/1 kV 4-adrig

BayEnergy® NA2X2Y-O 0,6/1 kV 4-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Freien und im Erdreich für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)2YSWAY-fl-TIMF

RE-2Y(St)2YSWAY-fl-TIMF

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type 03 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Two conductors twisted to a pair TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BayEnergy® (N)2X(L)2Y  0,6/1 kV  1-adrig

BayEnergy® (N)2X(L)2Y 0,6/1 kV 1-adrig

Querwasserdichtes Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den Schichtenmantel querwasserdicht. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-Y(St)YSWAY-fl-MP

RE-Y(St)YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED,ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BayEnergy® N2XY-O  0,6/1 kV  1-2-adrig

BayEnergy® N2XY-O 0,6/1 kV 1-2-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. Im Innen- und Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
RE-2Y(St)YQY-fl-PIMF

RE-2Y(St)YQY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)Y-fl-PIMF & RE-2X(St)Y-fl-PIMF

RE-2Y(St)Y-fl-PIMF & RE-2X(St)Y-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-PIMF,MULTİ-PAİR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / Blue cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)YQY-fl-TIMF

RE-2Y(St)YQY-fl-TIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)2YSWAY-fl-MP

RE-2Y(St)2YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 2SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1-1, 2-2-2,… Pair: Two conductors twisted to a pair Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,0 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,5 mm2 : max. 120 pF/m (≤2 pairs),max. 85 pF/m (all other pairs) Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
PV Drahtclips Metallkabelclips für Solarkabel - Solarkabelclips für PV Kabelmanagement

PV Drahtclips Metallkabelclips für Solarkabel - Solarkabelclips für PV Kabelmanagement

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen) Produkt-Spezifikationen Material: 301 Edelstahl Farbe: Weiß Verpackung: 100 Stück//Beutel 500 Stück//Beutel Umgebungstemperaturbereich: -40℃…+85℃ (IEC) SCC-ST/2 Geeignet für Kabel-OD: 2*4,0mm² Anwendung für Modul Material: 301 Edelstahl Farbe: Weiß Umgebungstemperaturbereich: -40℃…+85℃ (IEC)
RE-2Y(St)YQY-fl MP

RE-2Y(St)YQY-fl MP

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm
BayEnergy® N2XC2Y  0,6/1 kV  1-3-adrig

BayEnergy® N2XC2Y 0,6/1 kV 1-3-adrig

Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den HDPE-Außenmantel besonders widerstandsfähig. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF

RE-2Y(St)H-PIMF & RE-2X(St)H-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)H-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHEDRE-2X(St)H-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under separator tape of the pair screen Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP

RE-2Y(St)Y-fl & RE-2X(St)Y-fl MP

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

INSTRUMENTATION CABLES, EN 50288-7MULTİ-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)H&RE-2X(St)H-MP

RE-2Y(St)H&RE-2X(St)H-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1RE-2Y(St)H,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)H,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Pairs laid up in layers of optimum pitch Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl MP

RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl MP

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PVC INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)YwSWAYw cables are suitable. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Inner sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (Y): PVC compound, 70oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2YCYSWAY-fl-PIMF

RE-2YCYSWAY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, It can be manufacture as RE-2Y(St)CYSWAY-PIMF upon request. Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Inner sheath: PVC compound, EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Photovoltaik Außen-Solar-Kabelclips für Solarpanel-Kabel - Solar-Kabelclips aus Edelstahl für Kabelmanagement

Photovoltaik Außen-Solar-Kabelclips für Solarpanel-Kabel - Solar-Kabelclips aus Edelstahl für Kabelmanagement

Solar Kabelclip (Bitte erkundigen Sie sich nach Details zu verschiedenen Modellen) Produkt-Spezifikationen Material: 301 Edelstahl Farbe: Weiß Verpackung: 100 Stück//Beutel 500 Stück//Beutel Umgebungstemperaturbereich: -40℃…+85℃ (IEC) SCC-CT Geeignet für Kabelbinder mit ≤7mm Anwendung für Modulbündel Material: 301 Edelstahl Farbe: Weiß Umgebungstemperaturbereich: -40℃…+85℃ (IEC)
Kabelkonfektionierung

Kabelkonfektionierung

Kabelkonfektionen von bda connectivity sind auf hohe Leistung und lange Lebensdauer ausgelegt. Für die Projektanforderungen unserer Kunden stehen verschiedene Kabeltypen und Stecker zur Verfügung. Kabelkonfektionen von bda connectivity sind auf hohe Leistung und lange Lebensdauer ausgelegt. Extrem niedriges PIM garantiert Netzwerkleistung, während die Steifigkeit der Kabelstruktur für die Installation in härtester Umgebung und Verarbeitung sorgt. Für die Projektanforderungen unserer Kunden stehen verschiedene Kabeltypen und Stecker zur Verfügung. Wir bieten u.a. die Kabeltypen HF-Koaxialkabel, Strahlerkabel, optische Kabel usw., und Steckertypen N, 7/16, 4.3-10, TNC usw. Bitte wenden Sie sich an Ihren nächstgelegenen Vertriebsmitarbeiter, um weitere Informationen über die Kabelkonfektionierung zu erhalten.
Britian Silber

Britian Silber

Ladegerät Aluminium Anschluss Micro USB, Typ C und Lightning Silber Artikelnummer: 1280006 Gewicht: 0,065000 kg Größe: 120X1,8X0,8 Verpackungseinheit: 50 Zolltarifnummer: 85444993000
Kurzes USB-Kabel A an Mini B PREMIUM 50cm grau

Kurzes USB-Kabel A an Mini B PREMIUM 50cm grau

KURZES Mini-B USB-Kabel, 50cm, USB-A- an Mini-B-Stecker (5-polig), PREMIUM-Qualität: doppelt abgeschirmt, dickere Stromleitungen (28AWG/1P 24AWG/2C), Hi-Speed USB 2.0, grau Kurzes USB-Kabel A an Mini B PREMIUM 50cm grau Kurzbeschreibung KURZES Mini-B USB-Kabel, 50cm, USB-A- an Mini-B-Stecker (5-polig), PREMIUM-Qualität: doppelt abgeschirmt, dickere Stromleitungen (28AWG/1P 24AWG/2C), Hi-Speed USB 2.0, grau Technische Daten USB 2.0 Anschlusskabel A an Mini B PREMIUM-Qualität doppelt abgeschirmt (Alu-Folienschirm + Gefechtschirm) Datenleitungen AWG28/1P paarig verdrillt ("twisted pair") 5V Stromadern dicker mit AWG24/2C geschirmte Steckverbinder Kabelmaterial: USB 2.0 CABLE FULLY RATED 80°V 30V Ø ca. 4.1mm USB 2.0 kompatibel, abwärtskompatibel zu USB 1.1 geeignet für 480 MBit/s (high speed), 12 MBit/s (full speed) und 1.5 MBit/s (low speed) USB-Stecker Typ A (systemseitig) kleiner USB-Stecker Typ Mini B, 5-polig (an peripheres Gerät) Farbe: grau Länge: 0,5 Meter / 50cm Anwendung Mini USB Kabel in PREMIUM-Qualität Wir empfehlen den Einsatz von PREMIUM-Kabeln. Die Kupferadern für BusPower sind bei der PREMIUM-Qualität mit 24AWG/2C dicker ausgeführt. Hierdurch wird eine bessere Stromversorgung der angeschlossenen USB-Geräte sichergestellt. Insbesondere für längere Kabelverbindungen ist dies vorteilhaft. Akku-Ladezeiten werden durch dickere Kupferadern verringert. Doppelte Schirmung Zudem sind unsere PREMIUM-Kabel mit einem Geflechtschirm abgeschirmt. Unterstützt durch flexible Aluminiumfolie zur Schirmung werden so negative Auswirkungen elektro-magnetischer Störungen auf den Datenfluss reduziert. Ein ungestörten Datentransfer arbeitet schneller, was sich insbesondere bei großen Dateien bemerkbar macht. Die verbesserte Schirmung wirkt sich zudem positiv gegen Elektrosmog aus. Die zwei Datenleitungen des Kabels sind paarig verdrillt. Intern ist das Kabel entsprechend der USB-Norm mit Adern in den Farben gelb, weiß, schwarz und rot ausgestattet. Art.-Nr: CU-B04-GY-05 Länge: 0,5 m